Skip to main content

Schneider-Electric
ATV610D55N4

variable speed drive ATV610, 55 kW/75 HP, 380...460 V, IP20
Net discounted price 2,726.09 EUR
Available when ordered (delivery time: 56 working day(s))
Barcode: 3606480700620
Tariff code: 8504409590

Link to the manufacturers site: ATV610D55N4 - variable speed drive ATV610, 55 kW/75 HP, 380...460 V, IP20

Main

Range of produc: Easy Altivar 610

Product or component type: Variable speed drive

Product specific application: Fan, pump, compressor, conveyor

Device short name: ATV610

variant: Standard version

Product destination: Asynchronous motors

Mounting mode: Cabinet mount

EMC filter: Integrated conforming to IEC 61800-3 category C3 with 50 m

IP degree of protection: IP20

Type of cooling: Forced convection

Supply frequency: 50...60 Hz +/-5 %

Network number of phases: 3 phases

[Us] rated supply voltage: 380...460 V - 15...10 %

Motor power kW: 55 kW for normal duty; 45 kW for heavy duty

Motor power hp: 75 hp for normal duty; 60 hp for heavy duty

Line current: 111.5 A at 380 V (normal duty); 99.7 A at 460 V (normal duty); 95.9 A at 380 V (heavy duty); 84.0 A at 460 V (heavy duty)

Prospective line Isc: 22 kA

Apparent power: 79.5 kVA at 460 V (normal duty); 66.9 kVA at 460 V (heavy duty)

Continuous output current: 88 A at 2.5 kHz for heavy duty; 120 A at 2.5 kHz for normal duty

Maximum transient current: 132 A during 60 s (heavy duty); 132 A during 60 s (normal duty)

Asynchronous motor control profile: Optimized torque mode; Constant torque standard; Variable torque standard

Speed drive output frequency: 0.1…500 Hz

Nominal switching frequency: 2.5 kHz

Switching frequency: 1...8 kHz adjustable

Discrete input logic: 16 preset speeds

communication port protocol: Modbus serial

Option card: Slot A: communication card, Profibus DP V1; Slot A: digital or analog I/O extension card; Slot A: relay output card

Complementary

Output voltage: <= power supply voltage

Motor slip compensation: Automatic whatever the load; Adjustable; Not available in permanent magnet motor law; Can be suppressed

Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01 to 9000 s

Braking to standstill: By DC injection

Protection type: Thermal protection: motor; Motor phase break: motor; Thermal protection: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive

Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.012/50 Hz

Electrical connection: Control, screw terminal: 0.5...1.5 mm²; Line side, screw terminal: 70...120 mm²; Motor, screw terminal: 70...120 mm²

Connector type: 1 RJ45 (on the remote graphic terminal) for Modbus serial

Physical interface: 2-wire RS 485 for Modbus serial

Transmission frame: RTU for Modbus serial

Transmission rate: 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

Type of polarization: No impedance for Modbus serial

Number of addresses: 1…247 for Modbus serial

Method of access: Slave

Supply: External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection

Local signalling: 2 LEDs for local diagnostic; 1 LED (yellow) for embedded communication status; 2 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage

Width: 290 mm

Height: 762 mm; 922 mm with EMC plate

Depth: 323 mm

Net weight: 53 kg

analogue input number: 3

Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2, AI3 software-configurable temperature probe or water level sensor

Discrete input number: 6

Discrete input type: DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm; DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)

Input compatibility: DI1...DI6: logic input level 1 PLC conforming to IEC 61131-2; DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68

Discrete input logic: Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1); Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)

analogue output number: 2

Analogue output type: Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits

Sampling duration: 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input; 5 ms +/- 1 ms (DI5, DI6)configurable - pulse input; 10 ms +/- 1 ms (AQ1, AQ2) - analog output

Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output

Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output

Relay output number: 3

Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles

Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC

Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Isolation: Between power and control terminals

Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth

Environment

Noise level: 78 dB conforming to 86/188/EEC

Power dissipation in W: 969 W(forced convection) at 380 V, switching frequency 2.5 kHz; 131 W(natural convection) at 380 V, switching frequency 2.5 kHz

Volume of cooling air: 295 m3/h

Operating position: Vertical +/- 10 degree

Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Pollution degree: 2 conforming to IEC 61800-5-1

Vibration resistance: 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation: -15…45 °C (without derating); 45…60 °C (with derating factor)

Ambient air temperature for storage: -40…70 °C

Operating altitude: <= 1000 m without derating; 1000...4800 m with current derating 1 % per 100 m

Environmental characteristic: Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to IEC 60721-3-3

Standards: IEC 61800-3; Environment 2 category C3 IEC 61800-3; IEC 61800-5-1; IEC 60721-3

Marking: CE

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 47.000 cm

Package 1 Width: 59.000 cm

Package 1 Length: 87.000 cm

Package 1 Weight: 70.500 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1406021EN

Circularity Profile: ENVEOLI1406021EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Upgradeability: Upgradeable through digital modules and upgraded components

© 2018 Alplan Kft.