Schneider-Electric
ATV630D22N4
Tariff code: 8504409590
Link to the manufacturers site: ATV630D22N4 - variable speed drive ATV630 - 22kW/30HP - 380...480V - IP21/UL type 1
Main
Range of product: Altivar Process ATV600
Product or component type: Variable speed drive
Product specific application: Process and utilities
Device short name: ATV630
Variant: Standard version
Product destination: Asynchronous motors; Synchronous motors
EMC filter: Integrated with 50 m conforming to IEC 61800-3 category C2; Integrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protection: IP21 conforming to IEC 61800-5-1; IP21 conforming to IEC 60529
[Us] rated supply voltage: 380...480 V
Degree of protection: UL type 1 conforming to UL 508C
Type of cooling: Forced convection
Supply frequency: 50...60 Hz - 5...5 %
[Us] rated supply voltage: 380...480 V - 15...10 %
Motor power kW: 22 kW (normal duty); 18.5 kW (heavy duty)
Motor power hp: 30 hp normal duty; 25 hp heavy duty
Line current: 39.6 A at 380 V (normal duty); 34.4 A at 480 V (normal duty); 34.1 A at 380 V (heavy duty); 29.9 A at 480 V (heavy duty)
Prospective line Isc: 50 kA
Apparent power: 28.6 kVA at 480 V (normal duty); 24.9 kVA at 480 V (heavy duty)
Continuous output current: 46.3 A at 4 kHz for normal duty; 39.2 A at 4 kHz for heavy duty
Asynchronous motor control profile: Optimized torque mode; Constant torque standard; Variable torque standard
Synchronous motor control profile: Permanent magnet motor; Synchronous reluctance motor
Speed drive output frequency: 0.1…500 Hz
Nominal switching frequency: 4 kHz
Switching frequency: 2...12 kHz adjustable; 4...12 kHz with derating factor
Safety function: STO (safe torque off) SIL 3
Discrete input logic: 16 preset speeds
communication port protocol: Modbus TCP; Ethernet; Modbus serial
Option card: Slot A: communication module, Profibus DP V1; Slot A: communication module, PROFINET; Slot A: communication module, DeviceNet; Slot A: communication module, Modbus TCP/EtherNet/IP; Slot A: communication module, CANopen daisy chain RJ45; Slot A: communication module, CANopen SUB-D 9; Slot A: communication module, CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module; Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link; Communication module, BACnet MS/TP; Communication module, Ethernet Powerlink
Complementary
Design of frequency changer: U converter
Network frequency: 50...60 Hz
Ambient air transport temperature: -40…70 °C
Relative symmetric mains voltage tolerance: 10 %
Maximum output voltage: 480.0 V
Relative symmetric network frequency tolerance: 5 %
Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms
Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3
Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz
Nominal output power: 22.0 kW
4 quadrant operation possible: False
Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3
Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3
Capacity of DC link: 1500.0 µF
Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz
Operating element present: True
Number of HW interfaces serial TTY: 0
Power loss per device current dependent: 670.0 W
Power loss static current independent: 23.0 W
Number of output phases: 3
Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz
Number of input phases: 3
Number of inputs, potential-free: 0
Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz
Brake chopper integrated: False
Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms
Number of HW interfaces USB: 0
Number of HW interfaces other: 0
Optical interface present: False
Computer port: True
Supporting protocol for TCP/IP: True
Application in industrial area permitted: True
Application in domestic and commercial area permitted: False
Supporting protocol for PROFIBUS: True
Number of HW interfaces industrial Ethernet: 1
Number of inputs, bidirectional, not potential-free: 0
1 phase low current possible: False
Number of HW interfaces parallel: 0
Supporting protocol for KNX: False
Supporting protocol for ASI: False
Number of HW interfaces PROFINET: 0
Supporting protocol for CAN: True
Supporting protocol for INTERBUS: False
Supporting protocol for DeviceNet: False
Supporting protocol for SUCONET: False
Supporting protocol for LON: False
Supporting protocol for MODBUS: True
Supporting protocol for Data-Highway: False
Supporting protocol for PROFINET IO: True
Supporting protocol for PROFINET CBA: True
Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms
Supporting protocol for Foundation Fieldbus: False
Supporting protocol for SERCOS: False
Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz
Supporting protocol for DeviceNet Safety: False
Supporting protocol for INTERBUS-Safety: False
Supporting protocol for PROFIsafe: False
Supporting protocol for EtherNet/IP: True
Supporting protocol for AS-Interface Safety at Work: False
Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz
With safety function Safe torque off (STO): True
With sft fct Safe Stop 2 (SS2): False
With safety function Safe Stop 1 (SS1): False
Supporting protocol for SafetyBUS P: False
Supporting protocol for BACnet: False
Supporting protocol for other bus systems: False
Nominal output current: 46.3 A
With safety function Safe brake management (SBC/SBT): False
With safety function Safe Operating Stop (SOS): False
With safety function Safely Limited Position (SLP): False
With safety function Safely Limited Speed (SLS): False
With safety function Safe Speed Monitor (SSM): False
With safety function Safe Direction (SDI): False
Base load current at high overload: 39.2 A
Base load current at low overload: 46.3 A
Number of HW interfaces serial RS232: 0
With safety function Safe programmable logic: False
With safety function Safe Position (SP): False
EMC limit value (complied): True
Environmental class (during transport): Class 2C3 according to EN 60721-3-2; Class 2S1 according to EN 60721-3-2
Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Environmental class (during storage): Class 1C3 according to EN 60721-3-1; Class 1S2 according to EN 60721-3-1
Number of HW interfaces serial RS422: 0
Number of HW interfaces serial RS485: 1
Mounting mode: Wall mount
Maximum transient current: 50.9 A during 60 s (normal duty); 58.8 A during 60 s (heavy duty)
Network number of phases: 3 phases
Discrete output number: 0
Discrete output type: Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage: <= power supply voltage
Permissible temporary current boost: 1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty)
Motor slip compensation: Adjustable; Not available in permanent magnet motor law; Automatic whatever the load; Can be suppressed
Acceleration and deceleration ramps: Linear adjustable separately from 0.01...9999 s
Physical interface: Ethernet; 2-wire RS 485
Braking to standstill: By DC injection
Protection type: Thermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive
Transmission rate: 10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.012/50 Hz
Transmission frame: RTU
Electrical connection: Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16; Motor: screw terminal 16 mm²/AWG 6; Line side: screw terminal 10...16 mm²/AWG 8...AWG 6
Connector type: RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP; RJ45 (on the remote graphic terminal) for Modbus serial
Data format: 8 bits, configurable odd, even or no parity
Type of polarization: No impedance
Exchange mode: Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses: 1…247 for Modbus serial
Method of access: Slave Modbus TCP
Supply: External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling: 3 LEDs for local diagnostic; 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage
Width: 211 mm
Height: 546 mm
Depth: 232 mm
Net weight: 14.3 kg
Analogue input number: 3
Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number: 8
Discrete input type: DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibility: DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logic: Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number: 2
Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA
Sampling duration: 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output
Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AO1, AO2: +/- 0.2 % for analog output
Relay output number: 3
Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation: Between power and control terminals
Maximum output frequency: 500 kHz
Maximum associated fuse rating: 80.0 A
Maximum input current: 39.6 A
Functionality: Full
Specific application: Utility
IP degree of protection: IP21
Discrete and process manufacturing: Building - HVAC compressor centrifugal; Food and beverage processing other application; Mining mineral and metal fan; Mining mineral and metal pump; Oil and gas fan; Water and waste water other application; Building - HVAC screw compressor; Food and beverage processing pump; Food and beverage processing fan; Food and beverage processing atomization; Oil and gas electro submersible pump (ESP); Oil and gas water injection pump; Oil and gas jet fuel pump; Oil and gas compressor for refinery; Water and waste water centrifuge pump; Water and waste water positive displacement pump; Water and waste water electro submersible pump (ESP); Water and waste water screw pump; Water and waste water lobe compressor; Water and waste water screw compressor; Water and waste water compressor centrifugal; Water and waste water fan; Water and waste water conveyor; Water and waste water mixer
Power range: 15…25 kW at 380…440 V 3 phases; 15…25 kW at 480…500 V 3 phases
Motor starter type: Variable speed drive
Housing material: Plastic
Quantity per set: 1
enclosure mounting: Wall mounted
Environment
Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth
Noise level: 59.5 dB conforming to 86/188/EEC
Power dissipation in W: Natural convection: 68 W at 380 V, switching frequency 4 kHz; Forced convection: 505 W at 380 V, switching frequency 4 kHz
Volume of cooling air: 215 m3/h
Operating position: Vertical +/- 10 degree
Maximum THDI: <48 % from 80...100 % of load conforming to IEC 61000-3-12
Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree: 2 conforming to IEC 61800-5-1
Vibration resistance: 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation: -15…50 °C (without derating); 50…60 °C (with derating factor)
Ambient air temperature for storage: -40…70 °C
Operating altitude: <= 1000 m without derating; 1000...4800 m with current derating 1 % per 100 m
Standards: UL 508C; IEC 61800-3; Environment 1 category C2 IEC 61800-3; Environment 2 category C3 IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Product certifications: ATEX zone 2/22; CSA; TÜV; DNV-GL; UL; ATEX INERIS
Marking: CE
NEMA degree of protection: NEMA 1
Standards: UL 508C; IEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Overvoltage category: III
Regulation loop: Adjustable PID regulator
Noise level: 59.5 dB
Pollution degree: 2
Ambient air temperature for operation: -15…60 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 33.500 cm
Package 1 Width: 26.000 cm
Package 1 Length: 73.500 cm
Package 1 Weight: 17.580 kg
Unit Type of Package 2: S06
Number of Units in Package 2: 4
Package 2 Height: 90.000 cm
Package 2 Width: 60.000 cm
Package 2 Length: 80.000 cm
Package 2 Weight: 80.932 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1404008EN
Circularity Profile: ENVEOLI1404008EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.