Schneider-Electric
RE22R1QCMU
Tariff code: 8536490099
Link to the manufacturers site: RE22R1QCMU - Star-delta Timer Relay
Main
Range of produc: Harmony Timer Relays
Product or component type: Single function relay
Discrete output type: Relay
Device short name: RE22
Nominal output current: 8 A
[Uc] control circuit voltage: 24 V; 24...240 V
Contacts type and composition: 1 C/O
Connections - terminals: Screw connectors
[In] rated current: 5 A
Output type: Relay
Complementary
Contacts type and composition: 1 C/O timed contact, cadmium free
Time delay type: Star-delta
Time delay range: 10...100 s; 3...30 s; 0.1...1 s; 0.3...3 s; 0.05...0.5 s; 1...10 s; 30...300 s
Control type: Rotary knob; Diagnostic button
[Us] rated supply voltage: 24 V DC; 24...240 V AC 50/60 Hz
Input voltage: <= 2.4 V
Voltage range: 0.85...1.1 Us
Supply frequency: 50...60 Hz +/- 5 %
Connections - terminals: Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque: 0.6…1 N.m conforming to IEC 60947-1
Housing material: Self-extinguishing
Repeat accuracy: +/- 0.5 % conforming to IEC 61812-1
Temperature drift: +/- 0.05 %/°C
Voltage drift: +/- 0.2 %/V
Setting accuracy of time delay: +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Insulation resistance: 100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time: 120 ms on de-energisation
Immunity to microbreaks: 10 ms
Power consumption in VA: 35 VA at 240 V AC
Power consumption in W: 0.6 W at 24 V DC
Switching capacity in VA: 2000 VA
Minimum switching current: 10 mA at 5 V DC
Maximum switching current: 8 A
Maximum switching voltage: 250 V AC
Electrical durability: 100000 cycles, 8 A at 250 V, AC-1; 100000 cycles, 2 A at 24 V, DC-1
Mechanical durability: 10000000 cycles
[Uimp] rated impulse withstand voltage: 5 kV for 1.2…50 µs conforming to IEC 60664-1
Maximum delay response: 100 ms
Creepage distance: 4 kV/3 conforming to IEC 60664-1
Overvoltage category: III conforming to IEC 60664-1
Safety reliability data: MTTFd = 285.3 years; B10d = 270000
Mounting position: Any position
Mounting support: 35 mm DIN rail conforming to IEC 60715
Status LED: LED backlight green (steady) for dial pointer indication; LED yellow (steady) for output relay energised; LED yellow (fast flashing) for timing in progress and output relay de-energised; LED yellow (slow flashing) for timing in progress and output relay energised
Width: 22.5 mm
Net weight: 0.08 kg
Time delay type: Qc
Contacts type and composition: 1 C/O
Functionality: Star-delta starter timing
Environment
Dielectric strength: 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
Standards: UL 508; IEC 61812-1
Directives: 2004/108/EC - electromagnetic compatibility; 2006/95/EC - low voltage directive
product certifications: GL; CE; CCC; EAC; UL; CSA; RCM
ambient air temperature for operation: -20…60 °C
Ambient air temperature for storage: -40…70 °C
IP degree of protection: IP40 housing: conforming to IEC 60529; IP50 front face: conforming to IEC 60529; IP20 terminals: conforming to IEC 60529
Pollution degree: 3 conforming to IEC 60664-1
Vibration resistance: 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance: 15 gn not operating for 11 ms conforming to IEC 60068-2-27; 5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity: 95 % at 25…55 °C
Electromagnetic compatibility: Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4; Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5; Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5; Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3; Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6; Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4; Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11; Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 2.5 cm
Package 1 Width: 8.4 cm
Package 1 Length: 9.5 cm
Package 1 Weight: 90.0 g
Unit Type of Package 2: S02
Number of Units in Package 2: 40
Package 2 Height: 15.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 4.14 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 640
Package 3 Height: 80.0 cm
Package 3 Width: 80.0 cm
Package 3 Length: 60.0 cm
Package 3 Weight: 73.38 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1401008EN
Circularity Profile: ENVEOLI1401008EN
© 2018 Alplan Kft.