Schneider-Electric
LV481003
Tariff code: 8536490099
Link to the manufacturers site: LV481003 - Vigirex szivárgóáram védelmi relé RHU - 0.03..30 A - 0..5 s - 240 V
Main
Range: VigiPacT
Device short name: RHU
Product or component type: Residual current protection relay
Relay application: Monitoring relay; Protection relay
mounting support: Front panel
Earth-leakage protection class: Type A
Type of setting: Modbus address; Keypad
Residual earth-leakage sensitity adjustment type: Adjustable
Earth leakage current: 0.03…1 A, adjustable in step of 0.001 A; 1…30 A, adjustable in step of 0.1 A
Residual earth-leakage time delay adjustment type: Instantaneous for 0.03 A; Adjustable 0…4.5 s for 0.03…30 A adjustable in step of 10 ms
Threshold setting: 0.015...1 A adjustable in step of 0.001 A pre-alarm; 1...30 A adjustable in step of 0.1 A pre-alarm; 0.03...1 A adjustable in step of 0.001 A alarm; 1...30 A adjustable in step of 0.1 A alarm
Range compatibility: VigiPacT TOA earth leakage current sensor; VigiPacT A earth leakage current sensor; VigiPacT L earth leakage current sensor
[Ithe] conventional enclosed thermal current: 8 A
Minimum load: 10 mA at 12 V
[Us] rated supply voltage: 220...240 V AC 50/60 Hz 70...110 %
Power consumption in VA: 8 VA
Network rated voltage: 1000 V - AC at 50/60 Hz (maximum) ; 1000 V - AC at 400 Hz (maximum)
Earthing system: TT; TN-S; IT
[Uimp] rated impulse withstand voltage: 8 kV
Reset: Remote reset
Complementary
Test function: Remote test; Remote test (via communication); Local
Signal contacts composition: 1 C/O alarm fail-safe; 1 NO pre-alarm fail-safe
Type of measurement: Earth fault current internal measurement, range: 20...200 %, accuracy: +/- 20 %
Refresh time: 0.5 s
Communication service: Modbus slave
Tamperproof of settings: Protected by access code
Connections - terminals: Alarm circuit: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Alarm circuit: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12; Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12; Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12; Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12; Power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12; Pre alarm: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12; Pre alarm: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12
Wire stripping length: Alarm circuit: 6 mm; Relay test and fault reset: 6 mm; Sensor: 6 mm; Voltage presence: 6 mm; Power supply: 6 mm; Pre alarm: 6 mm
Tightening torque: Alarm circuit: 0.5 N.m; Relay test and fault reset: 0.5 N.m; Sensor: 0.5 N.m; Voltage presence: 0.5 N.m; Power supply: 0.5 N.m; Pre alarm: 0.5 N.m
Standards: EN/IEC 60947-2 Annex M; EN/IEC 60755; UL 1053; CAN/CSA C22.2 No. 144
Width: 72 mm
height: 72 mm
Depth: 117 mm
Cut-out dimensions: 68 x 68 mm
Net weight: 0.3 kg
IP degree of protection: IP40 front face: conforming to IEC 60529; IP30 other parts: conforming to IEC 60529; IP20 connection: conforming to IEC 60529
IK degree of protection: IK07 conforming to EN 50102
Mechanical robustness: Vibrations 13.2...100 Hz: 0.7 g; Vibrations 2...13.2 Hz: +/- 1 mm
Compatibility code: RH86M
Environment
Environmental characteristic: Exposure to damp heat not in service conforming to IEC 60068-2-30; Exposure to damp heat in service conforming to IEC 60068-2-56; Salt mist conforming to IEC 60068-2-52
Overvoltage category: IV
Electrical shock protection class: Class II
Electromagnetic compatibility: Conducted and radiated emissions: , B, conforming to CISPR 11; Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6; Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2; High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5; Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4; Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative humidity: 95 % at 55 °C
Pollution degree: 3 conforming to IEC 60664-1
ambient air temperature for operation: -25…55 °C
Ambient air temperature for storage: -40…85 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 8.5 cm
Package 1 Width: 11.0 cm
Package 1 Length: 15.5 cm
Package 1 Weight: 430.0 g
Unit Type of Package 2: S04
Number of Units in Package 2: 24
Package 2 Height: 30.0 cm
Package 2 Width: 40.0 cm
Package 2 Length: 60.0 cm
Package 2 Weight: 11.086 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant with Exemptions
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP2307009EN
Circularity Profile: ENVEOLI2307009EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins