Skip to main content

Schneider-Electric
ZBRA1

Relay Antenna, AC/DC, 5m cable output
Net discounted price 75.69 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3606480334689
Tariff code: 8526920090

Link to the manufacturers site: ZBRA1 - Relay Antenna, AC/DC, 5m cable output

Main

Range of produc: Harmony XB5R

Product or component type: Wireless and batteryless range

Device short name: ZBRA

Product destination: Wireless Schneider Electric ecosystem devices

Control station application: Transceiver (emission and reception)

Colour of base of enclosure: Black (RAL 9011)

Colour of cover: Transparent

Material: Polycarbonate

Transmission frequency: 2405 MHz for transmitter; 2405 MHz for receiver

Level or class: 5M00G7W

Antenna type: Omnidirectional

Complementary

Communication port protocol: Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4

Antenna gain: 0 dBi

Maximum sensing distance: 300 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna

Emission power: 3 mW

[Us] rated supply voltage: 24...240 V AC/DC 50/60 Hz - 10...10 %

Maximum power consumption in W: 4 W AC/DC

Operating position: Vertical

Status LED: 1 LED green for power ON; 1 LED green for emission signal

Overvoltage category: III conforming to IEC 60664-1

Rated short-duration power frequency withstand voltage: 4 kV 50 Hz conforming to IEC 60947-5-1

[Uimp] rated impulse withstand voltage: 4 kV

Electrical connection: 2 conductors cable 0.34 mm² - flexible - 5 m conforming to IEC 60947-1

Tightening torque: 0.6 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing plastic

Short-circuit protection: 0.4 A fuse type fast blow

Max power consumption in W: 1 mW

Number of channels: 1

modulation technique: O-QPSK

Bandwidth: 5 MHz

CAD overall height: 67 mm

CAD overall width: 93 mm

Net weight: 0.2 kg

Environment

Ambient air temperature for storage: -40…70 °C

Relative humidity: 90 % at -20…55 °C, without condensation conforming to ETSI EN 300 440-1

Electrical shock protection class: Class II conforming to IEC 61140

IP degree of protection: IP65 conforming to IEC 60529 55 °C 0.1 m

Pollution degree: 3 conforming to IEC 60664-1

IK degree of protection: IK03 conforming to IEC 62262

Radio agreement: RSS; SRRC; ANATEL, type III conforming to ETSI EN 301 489-3; ARIB T66, class 2 conforming to ETSI EN 301 489-3; FCC, category 2 conforming to ETSI EN 300 440-1; ICASA, category 1 conforming to ETSI EN 300 440-1

product certifications: CCC; BT 2006/95/EC; UL; GOST; CSA; CE; C-Tick

Directives: 1999/5/EC - R&TTE directive; 2004/108/EC - electromagnetic compatibility

Vibration resistance: +/-0.5 mm (f= 10…55 Hz) conforming to IEC 60068-2-6; 6 gn (f= 55…150 Hz) conforming to IEC 60068-2-6

Shock resistance: 25 gn (duration = 6 ms) for 6000 shocks conforming to IEC 60068-2-27; 15 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Insulation resistance: > 500 MOhm at 500 V DC conforming to NF C 20030

[Ui] rated insulation voltage: 250 V conforming to IEC 60664-1

Electromagnetic compatibility: Immunity for industrial environments conforming to IEC 61000-6-2; Conducted and radiated emissions class B conforming to CISPR 22; Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test - test level: 2 kV conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5; Conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6; Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11; Radiated emission conforming to ETSI EN 300 440-1; Conducted emission conforming to EN 300-489-1; Conducted emission conforming to ETSI EN 300 489-3; Radiated emission conforming to ETSI EN 300 440-2

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 8.000 cm

Package 1 Width: 8.000 cm

Package 1 Length: 18.700 cm

Package 1 Weight: 267.000 g

Unit Type of Package 2: S03

Number of Units in Package 2: 18

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 5.293 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP101106EN

Circularity Profile: ENVEOLI1103010EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.