Skip to main content

Schneider-Electric
XY2AU2

enabling switch - 2 NO + 1 NC - 1 NO additional contact - double insulated
Barcode: 3389110362015
Tariff code: 8536508090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XY2AU2 - enabling switch - 2 NO + 1 NC - 1 NO additional contact - double insulated

Main

range of product: Preventa XY2

product or component type: Enabling switch

component name: XY2AU

enclosure type: Double insulated

Complementary

contacts type and composition: 2 NO + 1 NC

installed device: 1 NO additional contact

operator position information: 3 positions

enclosure material: PA66

connections - terminals: Terminal block, 1 x 0.34...1 x 1.5 mm²

mechanical durability: 1000000 cycles

cable entry: 1 entry 7…13 mm

contact code designation: C300 AC-15, Ue = 125 V, Ie = 0.75 A conforming to IEC 60947-5-1 appendix A; C300 AC-15, Ue = 250 V, Ie = 1.5 A conforming to IEC 60947-5-1 appendix A; R300 DC-13, Ue = 125 V, Ie = 0.22 A conforming to IEC 60947-5-1 appendix A; R300 DC-13, Ue = 250 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 5 A

[Ui] rated insulation voltage: 125 V on supplementary contact; 250 V inside (pollution degree 2) conforming to IEC 60947-1; 250 V outside (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 2.5 kV conforming to EN 60947-1

positive opening: With conforming to IEC 60947-5-1 appendix K

contact operation: Slow-break

operating force: 12 N; 50 N

short-circuit protection: 4 A fuse protection by cartridge fuse type gG

net weight: 0.32 kg

Environment

standards: CSA C22.2 No 14; EN/IEC 60947-5-1; EN/IEC 60947-1; CULus 508

protective treatment: TC

ambient air temperature for operation: -10…60 °C

ambient air temperature for storage: -40…70 °C

vibration resistance: 6 gn (f= 5…55 Hz) conforming to IEC 60068-2-6

shock resistance: 10 gn for 11 ms conforming to IEC 60068-2-27

electrical shock protection class: Class II conforming to EN/IEC 61140

IP degree of protection: IP65 conforming to IEC 60529

IK degree of protection: IK06 conforming to EN 50102

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: X

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.