Skip to main content

Schneider-Electric
LV510407

circuit breaker EasyPact Vigi CVS100F, 36 kA at 415 VAC, 100 A rating TM-D trip unit, MH Vigi module, 4P 3d
Barcode: 3606480221149
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LV510407 - circuit breaker EasyPact Vigi CVS100F, 36 kA at 415 VAC, 100 A rating TM-D trip unit, MH Vigi module, 4P 3d

Main

range: EasyPact

range of product: EasyPact CVS100...250

product name: EasyPact CVS

product or component type: Earth leakage circuit breaker

device short name: Vigi CVS100F

device application: Distribution

poles description: 4P

protected poles description: 3D

neutral position: Left

earth-leakage protection: With

[In] rated current: 100 A at 40 °C

breaking capacity code: F

network type: AC

breaking capacity: 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

utilisation category: Category A

trip unit name: TM-D

trip unit technology: Thermal-magnetic

trip unit rating: 100 A at 40 °C

protection type: Short-circuit protection (magnetic); Overload protection (thermal); Earth-leakage protection

earth-leakage add-on module name: MH

Complementary

network frequency: 50/60 Hz

control type: Toggle

mounting mode: Fixed

mounting support: Backplate

upside connection: Front

downside connection: Front

connections - terminals: Screw connection

[Uimp] rated impulse withstand voltage: 8 kV conforming to EN/IEC 60947-2

thermal protection adjustment range: 70…100 A

[Ics] rated service breaking capacity: 18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

mechanical durability: 30000 cycles

electrical durability: 12000 cycles 415 V In conforming to IEC 60947-2

connection pitch: 35 mm

contact position indicator: Yes

neutral protection setting: No protection (3d)

long time pick-up adjustment type Ir: Adjustable

long time pick-up adjustment range: 0.7...1 x In

long time delay adjustment type: Fixed

instantaneous pick-up adjustment type Ii: Fixed

instantaneous pick-up adjustment range: 800 A

earth-leakage protection class: Class A

residual earth-leakage sensitity adjustment type: Adjustable 5 settings

[IΔn] residual earth-leakage sensitive adjustment: 0.3 A; 1 A; 3 A; 10 A; 30 A

residual earth-leakage time delay adjustment type: Adjustable 5 settings

[Δt] residual earth-leakage time delay adjustment: 0 ms 40 ms; 60 ms 140 ms; 150 ms 300 ms; 310 ms 800 ms

height: 236 mm

width: 140 mm

depth: 86 mm

net weight: 2.2 kg

compatibility code: CVS100

Environment

electrical shock protection class: Class II

standards: EN 60947-2; IEC 60947-2

product certifications: IEC; GOST

IP degree of protection: IP40

pollution degree: 3 conforming to IEC 60664-1

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -50…85 °C

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure: ENVPEP110231EN

Circularity Profile: ENVEOLI1102031EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins