Schneider-Electric
LV429141
Tariff code: 8536303099
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LV429141 - trip unit Micrologic 6.2 E for Compact NSX 100/160/250 circuit breakers, electronic, rating 40A, 4 poles 4d
Main
Range: ComPact
Range of product: ComPact NSX100...250
Product name: Micrologic
Product or component type: Trip unit
Trip unit name: Micrologic 6.2 E
Trip unit technology: Electronic
Range compatibility: ComPact NSX100; ComPact NSX160; ComPact NSX250
Device application: Distribution
Poles description: 4P
Protected poles description: 3t + OSN; 4t; 3t; 3t + N/2
Neutral position: Left
Trip unit protection functions: LSIG
Protection type: L : for overload protection (long time); S : for short time short-circuit protection; I : for instantaneous short-circuit protection; G : for ground fault protection
[In] rated current: 40 A at 40 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Complementary
Long time pick-up adjustment type Ir: Adjustable 9 settings
long time pick-up adjustment range: 18...40 A
long time delay adjustment type: Adjustable
[tr] long-time delay adjustment range: 15…400 s at 1.5 x Ir; 0.35…11 s at 7.2 x Ir; 0.5…16 s at 6 x Ir
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 1.5...10 x Ir
Short-time delay adjustment type: Adjustable
[tsd] short-time delay adjustment range: 0…0.4 s I²t=off; 0.1…0.4 s I²t=on
Instantaneous pick-up adjustment type Ii: Adjustable
Instantaneous pick-up adjustment range: 1.5...12 x In Compact NSX250; 1.5...15 x In Compact NSX100; 1.5...15 x In Compact NSX160
Ground-fault pick-up adjustment type: Adjustable
[Ig] ground-fault pick-up adjustment range: 0.2...1 x In for In = 40 A; 0.4...1 x In for In > 40 A; Ig enable on/off
Ground-fault time delay adjustment type -tg: Adjustable
[tg] Ground-fault time delay adjustment range: 0…0.4 s I²t=off; 0.1…0.4 s I²t=on
Earth-leakage protection: Without
Neutral protection setting: 0.5 x Ir (3t + N/2); 1 x Ir (4t); 1.6 x Ir (3t + OSN); No protection (3t)
Zone selective interlocking ZSI: With
Local signalling: Flashing LED (green) for ready to operate; LED 105 % Ir (red) for overload; LED 90 % Ir (orange) for overload
Display type: LCD display
type of measurement: Energy meter
Communication of data: Energy metering; Demand current and power; Time-stamped histories and event tables; Protection and alarm settings; Maintenance indicators; Power quality; Instantaneous and demand values; Maximeters/minimeters
Electrical data recording: Maintenance indicators
Environment
Standards: EN/IEC 60947-2; UL 508
Product certifications: EAC; CCC; Marine
Ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…85 °C
Packing Units
Unit Type of Package 1: Db
Number of Units in Package 1: 1
Package 1 Height: 9.5 cm
Package 1 Width: 11.0 cm
Package 1 Length: 15.0 cm
Package 1 Weight: 675.0 g
Unit Type of Package 2: Doboz
Number of Units in Package 2: 11
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 7.84 kg
Offer Sustainability
Sustainable offer status: Green Premium product
EU RoHS Directive: Compliant
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP120606EN
Circularity Profile: ENVEOLI120604EN
© 2018 Alplan Kft.