Skip to main content

Schneider-Electric
LC2D80P7

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 230 V AC coil
Net discounted price 481.96 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3389110457858
Tariff code: 8536490099

Link to the manufacturers site: LC2D80P7 - TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 230 V AC coil

Main

Range of product: TeSys Deca

Range: TeSys

Product name: TeSys Deca

Product or component type: Reversing contactor

Device short name: LC2D

Contactor application: Resistive load; Motor control

Utilisation category: AC-1; AC-3; AC-3e; AC-4

Device presentation: Preassembled with reversing power busbar

Poles description: 3P

Pole contact composition: 3 NO

[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC

[Ie] rated operational current: 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit; 55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit

Motor power kW: 22 kW at 220...230 V AC 50 Hz; 37 kW at 380...400 V AC 50 Hz; 45 kW at 415...440 V AC 50 Hz; 55 kW at 500 V AC 50 Hz; 45 kW at 660...690 V AC 50 Hz

Motor power hp: 20 hp at 200/208 V AC 60 Hz for 3 phases motors; 7.5 hp at 115 V AC 60 Hz for 1 phase motors; 15 hp at 230/240 V AC 60 Hz for 1 phase motors; 25 hp at 230/240 V AC 60 Hz for 3 phases motors; 60 hp at 460/480 V AC 60 Hz for 3 phases motors; 60 hp at 575/600 V AC 60 Hz for 3 phases motors

Control circuit type: AC at 50/60 Hz

[Uc] control circuit voltage: 230 V AC 50/60 Hz

Auxiliary contact composition: 1 NO + 1 NC

[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947

Overvoltage category: III

[Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 125 A (at 60 °C) for power circuit

Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1100 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current: 135 A 40 °C - 10 min for power circuit; 320 A 40 °C - 1 min for power circuit; 640 A 40 °C - 10 s for power circuit; 990 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit

Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 200 A gG at <= 690 V coordination type 1 for power circuit; 160 A gG at <= 690 V coordination type 2 for power circuit

Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit

[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1

Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue <= 440 V; 1.5 Mcycles 80 A AC-3 at Ue <= 440 V; 1.5 Mcycles 80 A AC-3e

Power dissipation per pole: 12.5 W AC-1; 5.1 W AC-3; 5.1 W AC-3e

Protective cover: With

Interlocking type: Mechanical

Mounting support: Plate; Rail

Standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508

Product certifications: UL; CSA; RINA; GOST; CCC; DNV; LROS (Lloyds register of shipping); GL; BV; UKCA

Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid; Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end; Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end; Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end; Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end; Power circuit: connector 1 cable(s) 4…50 mm²solid; Power circuit: connector 2 cable(s) 4…25 mm²solid

Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time: 20...35 ms closing; 6...20 ms opening

Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability: 4 Mcycles

Maximum operating rate: 3600 cyc/h 60 °C

Complementary

Coil technology: Without built-in suppressor module

Control circuit voltage limits: 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz; 1...1.1 Uc (55…70 °C):operational AC 50/60 Hz

Inrush power in VA: 245 VA 60 Hz cos phi 0.75 (at 20 °C); 245 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA: 26 VA 60 Hz cos phi 0.3 (at 20 °C); 26 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation: 6…10 W at 50/60 Hz

Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency: 25...400 Hz

Minimum switching current: 5 mA for signalling circuit

Minimum switching voltage: 17 V for signalling circuit

Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact

Insulation resistance: > 10 MOhm for signalling circuit

Contact compatibility: M11

Compatibility code: LC2D

Power range: 15…25 kW at 200…240 V 3 phases; 30…50 kW at 380…440 V 3 phases; 30…50 kW at 480…500 V 3 phases; 55…100 kW at 480…500 V 3 phases

Motor starter type: Reversing contactor

Contactor coil voltage: 230 V AC standard

Environment

IP degree of protection: IP20 front face conforming to IEC 60529

Climatic withstand: conforming to IACS E10

Protective treatment: TH conforming to IEC 60068-2-30

Pollution degree: 3

Ambient air temperature for operation: -40…60 °C; 60…70 °C with derating

Ambient air temperature for storage: -60…80 °C

Operating altitude: 0...3000 m

Fire resistance: 850 °C conforming to IEC 60695-2-1

Flame retardance: V1 conforming to UL 94

Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Shocks contactor open: 8 Gn for 11 ms; Vibrations contactor closed: 3 Gn, 5...300 Hz; Shocks contactor closed: 10 Gn for 11 ms

Height: 127 mm

Width: 182 mm

Depth: 158 mm

Net weight: 3.2 kg

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 19.0 cm

Package 1 Width: 19.0 cm

Package 1 Length: 25.5 cm

Package 1 Weight: 3.749 kg

Unit Type of Package 2: S03

Number of Units in Package 2: 2

Package 2 Height: 30 cm

Package 2 Width: 30 cm

Package 2 Length: 40 cm

Package 2 Weight: 7.944 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP110205EN

Circularity Profile: N/A

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.