Skip to main content

Schneider-Electric
LC1E1201U5

EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 12A - 240 V AC coil
Net discounted price 18.92 EUR
Available when ordered (delivery time: 33 working day(s))
Barcode: 3606480327902
Tariff code: 8536490099

Link to the manufacturers site: LC1E1201U5 - EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 12A - 240 V AC coil

Main

Range: Easy TeSys

Range of produc: Easy TeSys Control

Product or component type: Contactor

Device short name: LC1E

contactor application: Resistive load; Motor control

utilisation category: AC-1; AC-3

Poles description: 3P

[Ue] rated operational voltage: Power circuit: <= 690 V AC 50/60 Hz

[Ie] rated operational current: 25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit; 12 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

[Uc] control circuit voltage: 240 V AC 50 Hz

Complementary

Motor power kW: 3 kW at 220...230 V AC 50/60 Hz (AC-3); 5.5 kW at 380...400 V AC 50/60 Hz (AC-3); 5.5 kW at 415 V AC 50/60 Hz (AC-3); 5.5 kW at 440 V AC 50/60 Hz (AC-3); 7.5 kW at 500 V AC 50/60 Hz (AC-3); 7.5 kW at 660...690 V AC 50/60 Hz (AC-3)

Pole contact composition: 3 NO

[Ith] conventional free air thermal current: 25 A (at 55 °C) for power circuit

Irms rated making capacity: 120 A at 440 V AC for power circuit conforming to IEC 60947-4-1

Rated breaking capacity: 96 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current: 105 A 40 °C - 10 s for power circuit; 61 A 40 °C - 60 s for power circuit; 30 A 40 °C - 600 s for power circuit

Associated fuse rating: 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1; 25 A gG at <= 690 V coordination type 1 for power circuit

Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit

Power dissipation per pole: 0.36 W AC-3; 1.6 W AC-1

[Ui] rated insulation voltage: 690 V conforming to IEC 60947-4-1

Overvoltage category: III

Pollution degree: 3

[Uimp] rated impulse withstand voltage: 6 kV coil not connected to the power circuit conforming to IEC 60947

Mechanical durability: 10000000 cycles

Electrical durability: 1400000 cycles AC-3; 300000 cycles AC-1

Control circuit type: AC at 50 Hz

Control circuit voltage limits: 0.85...1.1 Uc (-5…55 °C):operational 50 Hz; 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz

Inrush power in VA: 95 VA 50 Hz cos phi 0.75 (at 20 °C); 95 VA 60 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA: 8.3 VA 50 Hz cos phi 0.3 (at 20 °C); 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)

Heat dissipation: 2…3 W for control circuit

Operating time: 12...22 ms on closing; 4...19 ms on opening

Maximum operating rate: 1800 cyc/h 60 °C

Connections - terminals: Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end

Tightening torque: Power circuit: 1.2 N.m; Control circuit: 1.2 N.m

Auxiliary contact composition: 1 NC

Minimum switching voltage: 17 V for control circuit

Minimum switching current: 5 mA for control circuit

Insulation resistance: > 10 MOhm for control circuit

Non-overlap time: 1.5 ms on energisation guaranteed between NC and NO contact; 1.5 ms on de-energisation guaranteed between NC and NO contact

mounting support: DIN rail; Plate

Environment

Standards: IEC 60947-1; IEC 60947-5-1; IEC 60947-4-1

product certifications: CE; EAC

IP degree of protection: IP2X conforming to IEC 60529

Protective treatment: TH (pollution degree 3) conforming to IEC 60068-2-30

Permissible ambient air temperature around the device: -20…70 °C at Uc; -60…80 °C storage; -5…55 °C operation

Operating altitude: 3000 m without derating

Fire resistance: 850 °C conforming to IEC 60695-2-1

Mechanical robustness: Vibrations contactor open (1.5 Gn, 5...300 Hz) ; Vibrations contactor closed (3 Gn, 5...300 Hz) ; Shocks contactor open (7 Gn for 11 ms) ; Shocks contactor closed (10 Gn for 11 ms)

height: 74 mm

Width: 45 mm

Depth: 80 mm

Net weight: 0.3 kg

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 5.000 cm

Package 1 Width: 7.500 cm

Package 1 Length: 8.500 cm

Package 1 Weight: 341.000 g

Unit Type of Package 2: S02

Number of Units in Package 2: 36

Package 2 Height: 15.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 12.580 kg

Unit Type of Package 3: P06

Number of Units in Package 3: 576

Package 3 Height: 75.000 cm

Package 3 Width: 60.000 cm

Package 3 Length: 80.000 cm

Package 3 Weight: 209.280 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1610006EN

Circularity Profile: ENVEOLI1610006

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.