Schneider-Electric
LC1D80008F7
Tariff code: 8536490099
Link to the manufacturers site: LC1D80008F7 - TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 110 V AC 50/60 Hz coil
Main
Range: TeSys
Range of product: TeSys Deca
product or component type: Contactor
Device short name: LC1D
Contactor application: Resistive load
Utilisation category: AC-1
Poles description: 4P
[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current: 125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit
[Uc] control circuit voltage: 110 V AC 50/60 Hz
Complementary
Compatibility code: LC1D
Pole contact composition: 2 NO + 2 NC
Protective cover: With
[Ith] conventional free air thermal current: 125 A (at 60 °C) for power circuit
Irms rated making capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 640 A 40 °C - 10 s for power circuit; 990 A 40 °C - 1 s for power circuit; 135 A 40 °C - 10 min for power circuit; 320 A 40 °C - 1 min for power circuit
Associated fuse rating: 200 A gG at <= 690 V coordination type 1 for power circuit; 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole: 12.5 W AC-1
[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 4 Mcycles
Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Control circuit type: AC at 50/60 Hz
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz; 0.3...0.6 Uc (-40…55 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz
Inrush power in VA: 245 VA 60 Hz cos phi 0.75 (at 20 °C); 245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA: 26 VA 60 Hz cos phi 0.3 (at 20 °C); 26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation: 6…10 W at 50/60 Hz
Operating time: 20...35 ms closing; 6...20 ms opening
Maximum operating rate: 3600 cyc/h 60 °C
Connections - terminals: Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: connector 1 4…50 mm² - cable stiffness: flexible without cable end; Power circuit: connector 2 4…25 mm² - cable stiffness: flexible without cable end; Power circuit: connector 1 4…50 mm² - cable stiffness: flexible with cable end; Power circuit: connector 2 4…16 mm² - cable stiffness: flexible with cable end; Power circuit: connector 1 4…50 mm² - cable stiffness: solid without cable end; Power circuit: connector 2 4…25 mm² - cable stiffness: solid without cable end
Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Mounting support: Rail; Plate
Contact compatibility: M1
Environment
Standards: EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product certifications: CCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC
IP degree of protection: IP20 front face conforming to IEC 60529
Protective treatment: TH conforming to IEC 60068-2-30
Climatic withstand: conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device: -40…60 °C; 60…70 °C with derating
Operating altitude: 0...3000 m
Fire resistance: 850 °C conforming to IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) ; Shocks contactor open (8 Gn for 11 ms) ; Vibrations contactor closed (3 Gn, 5...300 Hz) ; Shocks contactor closed (10 Gn for 11 ms)
Height: 127 mm
Width: 96 mm
Depth: 140 mm
Net weight: 1.84 kg
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 15.500 cm
Package 1 Width: 11.000 cm
Package 1 Length: 13.800 cm
Package 1 Weight: 1.784 kg
Unit Type of Package 2: S02
Number of Units in Package 2: 5
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 9.665 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP110205EN
Circularity Profile: N/A
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.