Schneider-Electric
KBA25ED2303TW
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: KBA25ED2303TW - STRAIGHT DISTRIBUTION LENGTH 25A 3M
Main
range: Canalis
range of product: Canalis
product or component type: Busbar trunking
device short name: KBA
product compatibility: KBA
Complementary
device application: Lighting; Power socket distribution
maximum radiated magnetic field: 2 pT
[Ue] rated operational voltage: 230...400 V
[Uimp] rated impulse withstand voltage: 4 kV
[Ui] rated insulation voltage: 690 V
[Ie] rated operational current: 25 A at 35 °C
network frequency: 50/60 Hz
[Icw] rated short-time withstand current: 0.44 kA
[Ipk] rated peak withstand current: 4.4 kA
thermal stress limit: 195 kA².s
THDI: 0…15 % 25 A; 15…33 % 20 A; 33…100 % 16 A
maximum voltage drop: <0.72 V with power factor = 1 at 50 Hz with 1A for 100 m long; <0.67 V with power factor = 0.9 at 50 Hz with 1A for 100 m long; <0.61 V with power factor = 0.8 at 50 Hz with 1A for 100 m long; <0.54 V with power factor = 0.7 at 50 Hz with 1A for 100 m long
linear resistance: 6.8 mΩ/m R20 20 °C phase conductor; 8.3 mΩ/m R1 35 °C at Inc and 50 Hz phase conductor; 0.02 mΩ/m X1 35 °C at Inc and 50 Hz phase conductor; 8.33 mΩ/m Z1 35 °C at Inc and 50 Hz phase conductor; 27.21 mΩ/m R0 20 °C symmetrical components method Ph/N; 0.85 mΩ/m X0 20 °C symmetrical components method Ph/N; 27.22 mΩ/m Z0 20 °C symmetrical components method Ph/N; 13.61 mΩ/m Rb0 20 °C impedance method Ph/Ph; 13.61 mΩ/m Rb0 20 °C impedance method Ph/N; 1.57 mΩ/m protective conductor; 19.4 mΩ/m R0 20 °C symmetrical components method Ph/PE; 0.38 mΩ/m X0 20 °C symmetrical components method Ph/PE; 19.41 mΩ/m Z0 20 °C symmetrical components method Ph/PE; 11.01 mΩ/m Rb0 20 °C impedance method Ph/PE; 16.6 mΩ/m Rb1 35 °C at Inc with impedance method Ph/Ph; 16.6 mΩ/m Rb1 35 °C at Inc with impedance method Ph/N; 12.5 mΩ/m Rb1 35 °C at Inc with impedance method Ph/PE; 0.04 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/Ph; 0.04 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/N; 0.035 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/PE
mounting mode: By clips
busbar description: Straight length
busbar trunking polarity: L + N + PE
number of circuits: 1
number of tap-off outlets: 3
control type: Communicating
standards: EN/IEC 61439-6; EN/IEC 60439-2
width: 3140 mm
depth: 30 mm
height: 46 mm
length: 3 m
colour: White (RAL 9003)
net weight: 2.4 kg
Quantity per set: Set of 6
Environment
IP degree of protection: IP55 conforming to EN/IEC 60529
IK degree of protection: IK06 conforming to EN/IEC 62262
ambient air temperature for operation: 0…35 °C (100 % of In); 35…40 °C (96 % of In); 40…45 °C (93 % of In); 45…50 °C (89 % of In); 50…55 °C (85 % of In)
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure: ENVPEP061101EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
Halogen content performance: Halogen free product