Skip to main content

Schneider-Electric
03050

Szerelőlap NS-INS250, függőleges, rögzített, billenőkaros kapcsoló, kábelcsatornába
In stock: 1 pc(s)
Barcode: 3303430030508
Tariff code: 7326909890

This product is discontinued.

This product is no longer manufactured, but we have it in stock. Please contact us for price and delivery information!

Link to the manufacturers site: 03050 - Szerelőlap NS-INS250, függőleges, rögzített, billenőkaros kapcsoló, kábelcsatornába

Main

range: Prisma

range of product: Prisma G

product or component type: Mounting plate

accessory / separate part category: Installation accessory

range compatibility: Prisma Pack 250 duct; Prisma G duct; Prisma P cubicle

enclosure/cubicle description: Floor-standing duct - width 300 mm; Wall-mounted duct - width 300 mm; Cubicle - width 400 mm depth 400 mm; Pack enclosure - width 300 mm

installed device: EasyPact: fixed CVS100...160 without earth leakage protection - control: toggle - vertical installation; EasyPact: fixed CVS250 without earth leakage protection - control: toggle - vertical installation; ComPact: fixed INS250 - control: direct front rotary handle - vertical installation; ComPact: fixed INV100 - control: direct front rotary handle - vertical installation; ComPact: fixed INV160 - control: direct front rotary handle - vertical installation; ComPact: fixed INV200 - control: direct front rotary handle - vertical installation; ComPact: fixed INV250 - control: direct front rotary handle - vertical installation; ComPact: fixed NSX100...160 without earth leakage protection - control: toggle - vertical installation; ComPact: fixed NSX250 without earth leakage protection - control: toggle - vertical installation; EasyPact: fixed CVS100...160 with earth leakage protection - control: toggle - vertical installation; EasyPact: fixed CVS250 with earth leakage protection - control: toggle - vertical installation; ComPact: fixed NSX100...160 with earth leakage protection - control: toggle - vertical installation; ComPact: fixed NSX250 with earth leakage protection - control: toggle - vertical installation; ComPact: plug-in NSX100...160 without earth leakage protection - control: toggle - vertical installation; ComPact: plug-in NSX250 without earth leakage protection - control: toggle - vertical installation; ComPact: plug-in NSX100...160 with earth leakage protection - control: toggle - vertical installation; ComPact: plug-in NSX250 with earth leakage protection - control: toggle - vertical installation

poles description: 1 x 3P: fixed INS250 vertical installation; 1 x 4P: fixed INS250 vertical installation; 1 x 3P: fixed INV250 vertical installation; 1 x 4P: fixed INV250 vertical installation; 1 x 3P: fixed INV100 vertical installation; 1 x 4P: fixed INV100 vertical installation; 1 x 3P: fixed INV160 vertical installation; 1 x 4P: fixed INV160 vertical installation; 1 x 3P: fixed INV200 vertical installation; 1 x 4P: fixed INV200 vertical installation; 1 x 3P: fixed CVS100...160 vertical installation; 1 x 4P: fixed CVS100...160 vertical installation; 1 x 3P: fixed CVS250 vertical installation; 1 x 4P: fixed CVS250 vertical installation; 1 x 3P: fixed NSX100...160 vertical installation; 1 x 4P: fixed NSX100...160 vertical installation; 1 x 3P: plug-in NSX100...160 vertical installation; 1 x 4P: plug-in NSX100...160 vertical installation; 1 x 3P: fixed NSX250 vertical installation; 1 x 4P: fixed NSX250 vertical installation; 1 x 3P: plug-in NSX250 vertical installation; 1 x 4P: plug-in NSX250 vertical installation

condition of use: Need additional plate (1M high) when installation of device is in vertical

number of vertical modules [50 mm]: 9 module(s): CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): CVS100...160 without earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure); 9 module(s): CVS250 without earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): CVS250 without earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): CVS250 without earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure); 9 module(s): INS250, direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): INS250, direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): INV100, direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): INV100, direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): INV160, direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): INV160, direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): INV200, direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): INV200, direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): INV250, direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): INV250, direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): NSX100...160 without earth leakage protection , front connection in 400 mm Widecubicle; 9 module(s): NSX100...160 without earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure); 9 module(s): NSX250 without earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 9 module(s): NSX250 without earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 9 module(s): NSX250 without earth leakage protection , front connection in 400 mm Widecubicle; 9 module(s): NSX250 without earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure); 13 module(s): CVS100...160 with earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 13 module(s): CVS100...160 with earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 13 module(s): CVS250 with earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 13 module(s): CVS250 with earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 13 module(s): NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 13 module(s): NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 11 module(s): NSX100...160 with earth leakage protection , front connection in 400 mm Widecubicle; 13 module(s): NSX100...160 with earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure); 13 module(s): NSX250 with earth leakage protection , direct with long terminal shield in 300 mm Widefloor-standing duct (cable coming from top or bottom of enclosure); 13 module(s): NSX250 with earth leakage protection , direct with long terminal shield in 300 mm Widewall-mounted duct (cable coming from top or bottom of enclosure); 11 module(s): NSX250 with earth leakage protection , front connection in 400 mm Widecubicle; 13 module(s): NSX250 with earth leakage protection , direct with long terminal shield in 300 mm WidePack enclosure (cable coming from top or bottom of enclosure)

standards: IEC 61439-2

product certifications: ASEFA

Complementary

protective treatment: Electrophoresis treatment and hot-polymerised polyester epoxy powder

surface finish: Matt; Smooth

colour: White (RAL 9001)

width: 300 mm

height: 250 mm

net weight: 0.54 kg

enclosure/cubicle width: 300 mm Prisma G floor-standing duct EasyPact CVS100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct EasyPact CVS100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure EasyPact CVS100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure EasyPact CVS100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct EasyPact CVS250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct EasyPact CVS250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure EasyPact CVS250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure EasyPact CVS250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct ComPact INS250 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INS250 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INS250 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INS250 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV100 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV100 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV100 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV100 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV160 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV160 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV160 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV160 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV200 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV200 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV200 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV200 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV250 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV250 fixed direct front rotary handle vertical 3P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact INV250 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G wall-mounted duct ComPact INV250 fixed direct front rotary handle vertical 4P 1 direct with long terminal shield 9 203 mm; 300 mm Prisma G floor-standing duct ComPact NSX100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct ComPact NSX100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct ComPact NSX100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct ComPact NSX100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 without fixed toggle vertical 3P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 without fixed toggle vertical 4P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 without plug-in toggle vertical 3P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 without plug-in toggle vertical 4P 1 front connection 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX100...160 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX100...160 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct ComPact NSX250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct ComPact NSX250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct ComPact NSX250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G wall-mounted duct ComPact NSX250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 without fixed toggle vertical 3P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 without fixed toggle vertical 4P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 without plug-in toggle vertical 3P 1 front connection 9 178 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 without plug-in toggle vertical 4P 1 front connection 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX250 without fixed toggle vertical 3P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX250 without fixed toggle vertical 4P 1 direct with long terminal shield 9 178 mm; 300 mm Prisma G floor-standing duct EasyPact CVS100...160 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS100...160 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct EasyPact CVS100...160 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS100...160 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct EasyPact CVS250 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS250 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct EasyPact CVS250 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct EasyPact CVS250 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct ComPact NSX100...160 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct ComPact NSX100...160 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct ComPact NSX100...160 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct ComPact NSX100...160 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 with fixed toggle vertical 3P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 with fixed toggle vertical 4P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 with plug-in toggle vertical 3P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX100...160 with plug-in toggle vertical 4P 1 front connection 11 278 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX100...160 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX100...160 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct ComPact NSX250 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct ComPact NSX250 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G floor-standing duct ComPact NSX250 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma G wall-mounted duct ComPact NSX250 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 with fixed toggle vertical 3P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 with fixed toggle vertical 4P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 with plug-in toggle vertical 3P 1 front connection 11 278 mm; 400 mm 400 mm Prisma P cubicle ComPact NSX250 with plug-in toggle vertical 4P 1 front connection 11 278 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX250 with fixed toggle vertical 3P 1 direct with long terminal shield 13 278 mm; 300 mm Prisma Pack 250 Pack enclosure ComPact NSX250 with fixed toggle vertical 4P 1 direct with long terminal shield 13 278 mm

Packing Units

Number of Units in Package 1: 1

Number of Units in Package 2: 240

Number of Units in Package 3: 30

Package 1 Height: 5.5 cm

Package 1 Length: 22.0 cm

Package 1 Weight: 600.0 g

Package 1 Width: 16.0 cm

Package 2 Height: 105.0 cm

Package 2 Length: 120.0 cm

Package 2 Weight: 161.624 kg

Package 2 Width: 80.0 cm

Package 3 Height: 30.0 cm

Package 3 Length: 60.0 cm

Package 3 Weight: 18.703 kg

Package 3 Width: 40.0 cm

Unit Type of Package 1: PCE

Unit Type of Package 2: P12

Unit Type of Package 3: S04

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure: ENVPEP121221EN

Halogen content performance: Halogen free plastic parts product

© 2018 Alplan Kft.